Mu2e ESS engineering meeting (22 Sep 2015)
Chaired by: Dr. Nagaslaev, Vladimir
-
State of drawings
-
Need a list of things to do
-
Ways to reduce foil deflection
-
Under std conditions and 1lb tension foil deflection is 97u
-
Reduction opportunities:
-
Increase tension – not enough
-
Reduce foil spacing – what is the pitch limit? Could be just first 20mm, whole sheet, how about Titanium foil sheet?
-
Programmed frame profile shape – need to follow exact field shape
-
Complexed shape of the cathode – narrow width in the first few cm? However: reducing the width of cathode twice reduces deflection by 25% only
-
Reducing E-field, this requires increasing betaX; deflection ~1/betaX
-
Action items:
-
VN: calculation of acceptable cathode geometry options
-
Matt: follow up on available Ti foil quality
-
Make a decision by next meeting Sept. 29
-
Will be the Keyence demonstration on Wednesday
-
Spring prototype
-
Matt: Tom Diehl (?) has a measurement system for DES structures – large scale + high precision
There are minutes attached to this event.