8–12 Oct 2018
Facility for Rare Isotope Beams
US/Eastern timezone

Measurements with the Stripping Foil Test Stand in the Linac4 Transfer Line

8 Oct 2018, 11:50
20m
1200 Lecture Hall (Facility for Rare Isotope Beams)

1200 Lecture Hall

Facility for Rare Isotope Beams

640 South Shaw Lane, East Lansing, MI 48824
Oral 2 - Beam charge strippers (foil, liquid, gas, plasma) Session 1- Beam Charge Strippers (foil, liquid, gas, plasma)

Speaker

Mr Wilhelmus Weterings (CERN)

Description

In 2020, after the CERN accelerators complex Long Shutdown 2 (LS2), a novel Linac4 (L4)-to-PS Booster (PSB) charge-exchange injection system will allow to transform the L4 160 MeV H− beam into H+ which will be injected into the four PSB superposed rings. For this, a 200 µg/cm2 carbon stripping foil will convert negative hydrogen ions (H−) into protons by stripping off the electrons. L4 is now performing operational reliability runs, which include a stripping foil test stand installed in the L4 transfer line. These tests will permit to gain experience on the fragile foils, test different foil materials and thicknesses, measure the efficiency and lifetime of the foils, and evaluate the foil changing mechanism as well as the interlocking functions. This paper briefly describes the stripping foil test stand setup, before reporting on the obtained important test results.

Primary author

Mr Wilhelmus Weterings (CERN)

Co-authors

Dr Chiara Bracco (CERN) Mrs Louise Jorat (CERN) Mr Pieter Van Trappen (CERN) Mr Remy Noulibos (CERN)

Presentation materials