Introduction

Measure the distributions of photocount arrival times as a function of current in the laser diode. We want to test whether we can use the time distributions to detect the transition of the diode from LED (chaotic) to laser (coherent) radiation states. This data will serve as test and calibration for the analysis of radiation from single electrons and electron bunches in IOTA.

Apparatus

MZI interferometer at ESB. Arm delay away from interference condition.

Interferometer configuration:

Event timer configuration (Picoquant HydraHarp 400):

Collected time-tagged photocount events from SPAD1 and SPAD2 as a function of current in the diode.

E-log entry: https://www-bd.fnal.gov/Elog/?orEntryId=231813.

Data on the iota-fast.bd network drive.

Data Sets

start_time diode_voltage_V diode_current_mA arm_flipper SPAD_shutter avg_rate_Hz acquisition_time_s HH_filename
2023-01-17 14:05:46 2.35 4.1600 IN OPEN 1.74245(93)e5 10 1405_ID_4_mA_flipper_in
2023-01-17 14:09:43 2.35 4.1600 OUT OPEN 3.1027(23)e5 3 1409_ID_4_mA_flipper_out_1
2023-01-17 14:10:10 2.35 4.1600 OUT OPEN 3.1525(23)e5 3 1409_ID_4_mA_flipper_out_2
2023-01-17 14:28:30 4.50 22.0000 OUT OPEN 3.0534(12)e6 1 1428_ID_22_mA_flipper_out
2023-01-17 14:30:57 4.50 22.0000 IN OPEN 1.78925(95)e6 1 1430_ID_22_mA_flipper_in
2023-01-17 14:34:42 1.90 0.8300 IN OPEN 23541(11) 100 1433_ID_083_mA_flipper_in
2023-01-17 14:39:12 1.90 0.8300 OUT OPEN 39219(20) 50 1438_ID_083_mA_flipper_out
2023-01-17 14:44:27 0.00 0.0000 OUT OPEN 759.4(19) 100 1444_ID_0_mA_flipper_out_shutters_open
2023-01-17 14:48:15 0.00 0.0000 IN OPEN 758.4(19) 100 1447_ID_0_mA_flipper_in_shutters_open
2023-01-17 15:15:35 6.50 0.0303 IN OPEN 1.37495(83)e6 1 1513_ID_30_uA_flipper_in
2023-01-17 15:44:07 6.50 0.0303 IN OPEN 1.35193(82)e6 1 1541_ID_30_uA_flipper_in
2023-01-17 15:49:43 2.30 0.0051 IN OPEN 19035.4(98) 100 1547_ID_5_uA_flipper_in
2023-01-17 15:55:12 3.61 0.0128 IN OPEN 1.30436(81)e5 10 1553_ID_13_uA_flipper_in
2023-01-17 16:06:46 2.30 0.0051 OUT OPEN 33304(18) 50 1606_ID_5_uA_flipper_out
2023-01-17 16:10:14 3.61 0.0128 OUT OPEN 2.3820(15)e5 5 1609_ID_13_uA_flipper_out
2023-01-17 16:13:18 6.50 0.0303 OUT OPEN 2.3397(11)e6 1 1612_ID_30_uA_flipper_out
2023-01-17 16:20:53 0.00 0.0000 OUT CLOSED 197.30(99) 100 1620_ID_0_uA_flipper_out_shutters_closed
2023-01-17 16:24:41 0.00 0.0000 OUT OPEN 751.5(19) 100 1624_ID_0_uA_flipper_out_shutters_open

Distribution of photocounts in a given time window

Limit cases:

(Need corrections for digital SPAD response? Pile-up?)

Histograms of number of counts in given time window

Interferometer in “beam-splitter” mode: arm 2 blocked.

Chosen time bins to keep the same average number of counts.

Fano factor vs. diode current

Distribution of intervals between photocount events

To do.

Conclusions

Does the distribution depend on diode current?