MSD Machine Operations Report Summary Monday, March 13, 2023 Proton Source 1. Mechanical/Vacuum a. Linac Tank 5 i. Epoxied the water line to stop or slow down the water to vacuum leak Friday ii. Got ion pumps back on Friday evening iii. Saturday lost power to the rougher which was backing the turbo and vented Tank 5 to atmosphere iv. Techs came in to get pumping on the tank and Ops helped get the ion pumps back on over the weekend v. Today will work with Linac group with trying to get the water back on 2. Fluids a. Nothing to report Main Injector/Recycler 1. Mechanical/Vacuum a. Early morning R:IP901D tripped MCR reset it with out issue b. Sunday afternoon I:IP603B tripped MCR reset it with out issue 2. Fluids a. Nothing to report External Beamlines 1. Mechanical/Vacuum a. F17 ion pumps continue to struggle against vacuum leak 2. Fluids a. Nothing to report Fluids – General 1. CUB a. Continuing with jogging LCW pumps in F-sector and bleeding air in CUB, trying to start up LCW pumps REM system today b. Effluent water still sitting in tanks 2 & 3 not transferred to tank 4 yet and need to send out sample for test results. No regen of column 2 until later in the week