    • 09:00 09:45
      fddaq-v5.2.0 topics 45m
      Speakers: Eric Flumerfelt (Fermilab), Kurt Biery (Fermilab), Roland Sipos (CERN)

      Relevant links:

       

    • 09:45 10:00
      Policy question about one aspect of system configurations 15m

      Why are most TC producers connected to the TC DataSubscriberModule (actually data-reader-mlt), but the RandomTriggerCandidateMaker is connected directly to the TriggerDataHandlerModule (def-tc-handler-10000)?

      (Apologies if this is more of a question for DataSelection folks...)

      Background: we see the MLT and the ConnectivityService using a lot of CPU when we run the minimal_system_quick_test. Pierre tracked this down to a dangling connection (only one process/module, not two), and to some very fast re-trying to connect to the non-existent other end of the connection.

      Some notes about the diagrams that are attached to this agenda contribution:

      • the files are in SVG format, and in my experience, they are straightforwardly displayed by web browsers
      • the "minsysQT" diagrams show aspects of the configuration that is used in the minimal_system_quick_test automated regression test (in the daqsystemtest package)
      • the "dstExample" diagrams show aspects of the local-1x1-config example configuration that is provided in the daqsystemtest repo, config/daqsystemtest subdirectory
      Speakers: Kurt Biery (Fermilab), Pierre Lasorak (Imperial College London)