Speaker
Dr
Raffaella Donghia
(LNF-INFN)
Description
The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus.
The Mu2e detector is composed of a tracker and an electromagnetic
calorimeter and an external veto for cosmic rays.
The calorimeter plays an important role in providing excellent particle identification capabilities, a fast online trigger filter while aiding the track reconstruction capabilities.
The calorimeter requirements are to provide a large acceptance for ~100 MeV electrons and reach:
1) a time resolution better than 0.5 ns @ 100 MeV;
2) an energy resolution O(10%) @ 100 MeV;
3) a position resolution of 1 cm.
The calorimeter consists of two disks, each one made of 674 pure CsI
crystals readout by two large area 2x3 array of UV-extended
SiPMs of 6x6 mm^2 dimensions.
A large scale prototype has also been constructed and tested at the beam test facility in Frascati. It consists of 51 pre-production crystals readout by a Mu2e SiPM.
Summary
All the test and progresses done to define the calorimeter design, the satisfying results obtained with the test beam of the prototype as well as the actual production phase will be presented.
Primary authors
Dr
Luca Morescalchi
(University of Pisa)
Dr
Raffaella Donghia
(LNF-INFN)