Conveners
Survey & Alignment of Beamline and Machine Components
- Johannes Prenting (DESY)
Survey & Alignment of Beamline and Machine Components
- David Martin (ESRF)
Mr
Jean-Christophe GAYDE
(CERN)
11/09/2012, 10:15
Survey & Alignment of Beamline and Machine Components
Paper
In the frame of the HIE Isolde project most of the existing ISOLDE REX line will be replaced by a superconducting linac in order to upgrade the energy and intensity of the REX ISOLDE facility at CERN. The linac will be based on the staged construction and installation of six cryomodules, four of them housing 5 high-β superconducting cavities and one superconducting solenoid, the two remaining...
Mr
Mark Emamian
(Duke University)
11/09/2012, 10:40
Survey & Alignment of Beamline and Machine Components
Paper
Duke Free Electron Laser Laboratory (DFELL) located on the campus of Duke University is a dedicated facility for tunable free electron lasers. In this article, a novel design and alignment technique will be presented as part of our recent upgrade to the south straight section of the DFELL storage ring beamline. This assembly consists of a 14.5 meters long kinematic platform which is capable...
Dr
Virgil Bocean
(Fermi National Accelerator Laboratory)
11/09/2012, 11:05
Survey & Alignment of Beamline and Machine Components
Paper
In the context of today’s global interest in the neutrino research programs, with special emphasis on long baseline neutrino oscillation experiments, the LBNE project at Fermilab receives special attention as the world's highest-intensity neutrino beam to be sent 1,300 kilometres straight through the earth to an underground detector located 1 mile deep at the Sanford Underground Research...
Dr
Chenghao Yu
(Brookhaven National Laboratory)
11/09/2012, 13:00
Survey & Alignment of Beamline and Machine Components
Paper
The ongoing NSLS II project requires +/-30 micron alignment accuracy for the 6 or 7 mangets in each girder assembly. The vibrating wire technique used to alignment magnets in one girder can achieve a couple of micron precision. However, the tranportation and manner change of supporting will change the girder profile, hence the magnet alignment, to the extent of bigger than +/-50 micron.This...
Mr
jiandong yuan
(Institute of Modern Physics , Chinese Academy of Sciences)
11/09/2012, 13:25
Survey & Alignment of Beamline and Machine Components
Paper
the biggest challenges in the design of measuring scheme of Heavy Ion Therapy Facility in Lanzhou is the vertical treatment segment of high-energy transport line which is out of sight and high precision requirements, by using the laser tracker, Portable three coordinate measuring machine and digital levels and so on, and data processing software: SpatialAnalyzer, this article completed the...
Mr
tong wang
(Institute of High Energy Physics, Chinese Academy of Sciences)
11/09/2012, 13:50
Survey & Alignment of Beamline and Machine Components
Paper
China Spallation Neutron Source(CSNS) mainly consists of an H- linac about 197m in length, a proton rapid cycling synchrotron(RCS) about 228m in circumference, the linac to RCS beam transport (LRBT) about 40m in length, and the RCS to target transport(RTBT) about 144m in length. It is designed to accelerate proton beam pulses striking a solid metal target to produce spallation neutrons. The...