21–26 Jul 2024
NIU Naperville Conference Center
US/Central timezone

X-ray induced acoustic computed tomography with laser-wakefield accelerated sources: a simulation study

25 Jul 2024, 17:40
20m
room 261

room 261

WG6

Speaker

Jose Alejandro Franco Altamirano (The University of Texas at Austin)

Description

An x-ray excitation in a medium can cause localized heating (<mK) and thermoelastic expansion, inducing a detectable ultrasonic emission which potentially enables low-dose, 3D imaging [1]. For effective ultrasonic emission, the dose should be deposited faster than the stress confinement time of the medium, ~ns for many applications. This modality has been studied in medical linear accelerators (LINAC’s) [2] and more recently in a synchrotron [3]. LINAC’s suffer from long pulses (~μs) and synchrotrons, although successful, are not viable for this application due their size and cost. Laser Wakefield Accelerators (LWFA’s), on the other hand, produce femtosecond radiation and are more readily available, making them a candidate to explore XACT. Here, we compare Monte Carlo (GEANT4) simulated dose deposition [4] and acoustic responses from Inverse-Compton scattering radiation, Bremsstrahlung radiation and electrons (all these sources generated by a LWFA) for two applications: (1) imaging of metallic markers in water and (2) imaging of a cortical-trabecular bone configuration embedded in water. Advantages from each radiation source are discussed.
[1] Samant, P., et al. X-ray induced acoustic computed tomography, Photoacoustics 19, 100177, https://doi.org/10.1016/j.pacs.2020.100177 (2020)
[2] Xiang, L., et al. X-ray acoustic computed tomography with pulsed x-ray beam from a medical linear accelerator, Med. Phys. Lett. 40 (1) http://dx.doi.org/10.1118/1.4771935, (2013).
[3] Choi, S., et al. Synchrotron X-ray induced acoustic imaging, Scient. Rep. 11:4047, https://doi.org/10.1038/s41598-021-83604-3. (2021).
[4] Agostinelli, S. et al. GEANT4 – a simulation toolkit, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 506, 250-303, https://doi.org/10.1016/S0168-9002(03)01368-8 (2003).

Working group WG6 : Radiation generation, medical and industrial applications

Primary author

Jose Alejandro Franco Altamirano (The University of Texas at Austin)

Co-authors

Michael Downer (UT - Austin) B. Manuel Hegelich (University of Texas at Austin and Tausystems) Philip Franke (Tau Systems Inc) Calin Hojbota (University of Texas at Austin) Prof. Xiang Liangzhong (UC Irvine) Dr Prabodh Pandey (UC Irvine) Dr Dung Phan (The University of Texas at Austin)

Presentation materials