Vivek asked if there were any nutaus produced in the optimized beam that reach the detector. No, assumed to be none.
Diego asks why NC events aren't considered? Miraima says they are considered as backgrounds in electron and rho channels. Interactions here are in ND-LAr
Leo asks on slide 5 where do curves come from? The data that is being fit is MC sample of muons in gas momentum is reconstructed gas using GArsoft.
Alysia asked about on vs off axis. Miriama said preliminary studies show that it does not help. You lose a lot of nutau when you go off axis.
Tanaz: Great to see that these studies are using GArsoft. Might be helpful to share instructions to other BSM analyses. Leo notes that one can get started with GArsoft at https://github.com/DUNE/garsoft
Vivek: How long data taking is shown here? One year.