Please read these instructions before posting any event on Fermilab Indico

Indico will be unavailable on Wed, Jan 15th from 7-7:30am CST due to server maintenance.

4–8 Jun 2018
US/Eastern timezone

NOVA Medium energy target ME-1 autopsy, procedure and equipment

5 Jun 2018, 11:10
20m
1200 FRIB Bldg

1200 FRIB Bldg

Oral 3-Post Irradiation Examination Session 3-Post Irradiation Examination

Speaker

Mr Vladimir Sidorov (Fermilab)

Description

The purpose of the Medium energy target autopsy is the observation of the graphite fins. The graphite fins are major component of the target that are taking beam during operation. The target ME-1 is cooled down more than one year, but is still high radioactive. The target is delivered to the C-0 Remote Handling facility and placed on the stands inside the work cell by crane and aligned with the fixture. The work cell is equipped with manipulators, lead glass window and video cameras. The fixture has the high torque power tool that is used for a removing the target downstream end flange. The cart with video cameras is inserted into the opened target canister by manipulator and traveling there observing target fins. The video is translated to the video center located outside of the work cell.

Primary author

Mr Vladimir Sidorov (Fermilab)

Presentation materials

There are no materials yet.